Close Menu
Machinery Asia
  • Home
  • Industry News
  • Heavy Machinery
  • Backhoe Loader
  • Excavators
  • Skid Steer
  • Videos
  • Shopping
  • News & Media
Facebook X (Twitter) Instagram
Facebook X (Twitter) Instagram
Machinery Asia
Subscribe
  • Home
  • Industry News
  • Heavy Machinery
  • Backhoe Loader
  • Excavators
  • Skid Steer
  • Videos
  • Shopping
  • News & Media
Machinery Asia
You are at:Home » Optimizing HVAC for Wildfire Challenges: Expert Advice
Industry News

Optimizing HVAC for Wildfire Challenges: Expert Advice

Machinery AsiaBy Machinery AsiaJuly 5, 2023No Comments3 Mins Read
Facebook Twitter Pinterest LinkedIn Tumblr Email
Share
Facebook Twitter LinkedIn Pinterest Email Tumblr

With unprecedented wildfires in Canada and the increased likelihood of future wildfire activity in North America, Buro Happold’s experts offer advice on how to minimize pollutants in buildings and effective HVAC strategies for AECO professionals.

To protect against smoke infiltration and reduce the impacts of fine particles, called PM2.5, Justin Schultz of Buro Happold’s San Francisco office, as well as John Rozeluk of the Los Angeles office, present solutions to building owners with the aim of reducing health risks in buildings. occupants Both engineers bring extensive experience in building decarbonization and sustainability, as well as wildfire and smoke impact design in the United States.

Wildfire Season Considerations

Current guidance for the wildfire season is to use a high degree of recirculation for ventilation. New buildings and renovations now take this into account to provide energy efficient and cost effective solutions. Obstacles to maintaining a healthy indoor environment include (i) clogged filters in air handling units (AHUs) and (ii) smoke-contaminated fresh air supplies.

Possible interventions and example scenarios offered by Buro Happold experts include:

Inevitable central air recirculation

When air recirculation cannot be avoided or sufficiently reduced, building owners should consider exhaust air purifiers and high-quality filters, known as air filters of high efficiency particles (HEPA) classified MERV 15. The minimum efficiency report value (MERV) indicates the effectiveness of the air filter in reducing particles and pollutants in the air.

Mixed mode ventilation

A mixed mode ventilation system is suitable for natural ventilation most of the time. In the event of poor air quality due to wildfires, a local mechanical ventilation system with heat recovery (MVHR) can be used to provide fresh air.

Local modifications to centralized systems

When only local modifications can be made to a centralized HVAC system, building owners can consider room modifications, such as forming discrete bulkheads to allow horizontal air intake.

Displacement ventilation / UFAD

Underfloor air distribution (UFAD) ventilation introduces air at low levels with a unidirectional air path to extraction outlets located higher in interior spaces. This washes clean air over the occupants and draws pollutants into the ceiling.

“We have to build resilience and flexibility into our designs and engineering, in order to respond appropriately to anything that might happen. During the pandemic, we were trying to increase the volume of outside air and reduce recirculation, which is the opposite of what we need in order to exclude wildfire smoke and filter out particulates.Also, keep in mind that the energy demand to push air through HEPA or MERV 15 filters is very high, when most days a MERV 13 filter is sufficient. Architects and engineers must consider how to design ventilation systems that can be switched from normal use mode to configurations more appropriate for given crisis conditions. This will balance healthy air quality with overall energy use and operating costs,” says Rozeluk, responding to an inquiry from The construction specifier, regarding the role that architects and engineers can play in mitigating the effects of bushfires on IAQ. He added: “We should also explore options for managing the air pressure inside a building, so that in the event of a bushfire, you can resist air entering through typical openings and pathways of the wrapper, reducing the infiltration of smoke-borne particles.”

Source link

Share. Facebook Twitter Pinterest LinkedIn Tumblr Email
Previous ArticleSkanska JV lands £219m airbase job
Next Article Holocaust Memorial cost increases by 35%
Machinery Asia
  • Website

Related Posts

Two Pressures, One Channel: Conservation Meets Geopolitics in Panama

June 24, 2026

State Audit Clouds Future of Proposed NC Outer Banks Bridge

June 24, 2026

Gilbane-Turner JV leases $2.1 million stadium to Buffalo Bills

June 24, 2026
Leave A Reply Cancel Reply

  • Facebook
  • Twitter
  • Instagram
  • Pinterest
Don't Miss

Two Pressures, One Channel: Conservation Meets Geopolitics in Panama

State Audit Clouds Future of Proposed NC Outer Banks Bridge

Gilbane-Turner JV leases $2.1 million stadium to Buffalo Bills

Grant Certainty emerges as new failure in talks on transport project

Popular Posts

Two Pressures, One Channel: Conservation Meets Geopolitics in Panama

June 24, 2026

State Audit Clouds Future of Proposed NC Outer Banks Bridge

June 24, 2026

Gilbane-Turner JV leases $2.1 million stadium to Buffalo Bills

June 24, 2026

Grant Certainty emerges as new failure in talks on transport project

June 24, 2026
Heavy Machinery

What to check before towing a car trailer in the summer

June 24, 2026

Why dump trailer maintenance is important for long-term use

June 17, 2026

Top 5 Trailer Safety Mistakes to Avoid Before Towing

June 11, 2026

How to Choose a Gooseneck Tilt Equipment Trailer for Your Business

June 8, 2026

Subscribe to Updates

Get the latest creative news from FooBar about art, design and business.

Type above and press Enter to search. Press Esc to cancel.